LEGION Model Builder Help

Setting Waiting Location parameters

The next procedure is concerned with the portion of the ‘Edit Delay Point’ dialog box labelled 'Waiting Location'. These parameters combine with the Dispersal Points to determine the distribution of Entities in the area of the Delay Point: basically they define where people choose to wait until they move on to another target.

The parameters you need to set are concerned with Decision, Dispersion and Factor.

  • Decision

    This refers to how each delayed Entity will try to reach the point where it wants to wait. This decision is based on one of these three considerations:

    • Distance–an Entity will not come to rest until it has reached its desired waiting point.
    • Time–an Entity will estimate the time it will take to get to its desired waiting point at its preferred speed. It will then allow itself that much time to reach its waiting point and will stop when the time runs out.
    • Time and Distance–this is similar to the Distance option but applies a user-specified Maximum time.
  • Dispersion

    This refers to how delayed Entities attempt to distribute themselves between the point where they entered the area of the Delay Point and the Dispersal Point they are heading for.

    • The Linear function has an associated Factor setting

      A Factor value of 1 distributes Entities in a uniform pattern along a line from their point of entry to their FDP; a Factor of 100 distributes Entities closer to the FDP; a Factor of 0.001 distributes Entities closer to their point of entry.

    • The Boltzmann function has an associated Ratio setting

      The ratio skews the distribution of Entities according to the formula: 1:x, where x is a number you define.

To set Waiting Location parameters:

  1. Select one of the three options from the Decision drop-down menu:
    • Distance
    • Time
    • Time and Distance
  2. Select an option from the Dispersion drop-down menu:
    • Linear
    • Boltzmann
  3. Depending on the Dispersal method you selected, enter a Factor value or a Ratio value.
  4. Click on the Additional Parameters tab and see the following procedure.
  5. In the 'Link Options' area, select one of these two options:
    • Revert to final destination (Entities will proceed to wards this target or targets)
    • Specify links

    If you select 'Specify link', click on the 'Links' tab and add your target objects manually following the steps in Linking methods ).

  6. If you need to test your model against required regulatory flow rates you may wish to set a maximum value for 'Flow Rate Limiting'. To do so, check the box Maximum and enter a value for people/minute in the adjacent field.